Deltabar S FMD76 |
 |
Deltabar S with front flush ceramic measuring diaphragm. Overlod-resistant with function-monitoring. Communication via HART, PROFIBUS PA or FOUNDATION Fieldbus. |
 |
Areas of application
|
The Deltabar S differential pressure transmitter is used for the following measuring tasks: |
|
|  | Level, volume or mass measurement in liquids
|  | Differential pressure monitoring, e.g. of filters and pumps
|  | International usage thanks to wide range of approvals |
|
| |
|
|
Technical data
|
Reference accuracy:
|
up to 0.075% of the set span,
PLATINUM version: 0.05% of the set span
|
|
Measuring range:
|
from -100...+100 mbar to -3...+3 bar
|
|
Overload:
|
on one side: max. 100 bar
|
|
Process temperature:
|
-20...+85°C (-4...+185°F)
|
|
Ambient temperature:
|
-20...+85°C (-4...+185°F)
|
|
Certificates:
|
ATEX, CSA, FM, NEPSI, IECEx
|
|
Specialities:
|
- Abrivasion-resistant and corrosion-resistant
- No diaphragm-seal temperature effects
- Metal-free measurement possible with ECTFE-coated process connection |
|
| |
|
| |
|
|