Enter at least 2 characters to start the search.

Ultrasonic measurement
Time-of-Flight
Prosonic FMU43

Prosonic FMU43 ©Endress+Hauser

Time-of-Flight measuring principle

Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 15m

The Prosonic FMU43 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks, agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate.

Hitra izbira

Izberite med predlaganimi možnostmi
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

or

Individualna konfiguracija

Nadaljujte z izbiranjem med vsemi možnostmi
  • Prednosti

    • Reliable non-contact measurement

    • Quick and simple commissioning via menu-guided on-site operation with four-line plain text display, 7 languages selectable

    • Envelope curves on the on-site display for simple diagnosis

    • Hermetically sealed and potted sensor

    • ...

  • Področje uporabe

    Two-wire or four wire instrument for continuous non-contact level and flow measurement.

    • Process connection: Flange

    • Temperature: -40 to +80°C (-40 to +176°F)

    • Pressure: +0.7 to +2.5bar (+10 to +36psi)

    • Maximum measuring distance: Liquids 15m (50ft),...

Details

  • [h5] TEST

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    4-wire (HART), PROFIBUS PA, FOUNDATION Fieldbus

  • Accuracy

    +/- 4 mm or +/- 0.2 %of set measuring range 1)

  • Ambient temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process pressure absolute / max. overpressure limit

    0.7 bar ... 2.5 bar abs
    (10 psi ... 36 psi)

  • Main wetted parts

    unsaturated polyester, 316 Ti

  • Process connection

    DN 100, ASME 4"

  • Blocking distance

    0.6 m (2 ft)

  • Max. measurement distance

    7 m (23 ft)

  • Communication

    4 ... 20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, NEPSI

  • Application limits

    Take notice of range diagram

  • [h5] TEST

    Ultrasonic

  • Characteristic / Application

    Compact ultrasonic transmitter

  • Supply / Communication

    4-wire (HART), PROFIBUS PA, FOUNDATION Fieldbus

  • Accuracy

    +/- 4 mm or +/- 0.2 %of set measuring range

  • Ambient temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process temperature

    -40 °C ... 80 °C
    (-40 °F ... 176 °F)

  • Process pressure absolute / max. overpressure limit

    0.7 bar ... 2.5 bar abs
    (10 psi ... 36 psi)

  • Main wetted parts

    Unsaturated Polyester, 316 Ti

  • Process connection

    DN 100, ASME 4"

  • Blocking distance

    0.6 m (2 ft)

  • Application

    Application

  • Max. measurement distance

    Max. measurement distance

  • Communication

    4 ... 20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, NEPSI

  • Application limits

    Application limits

Dokumenti / Priročniki / Softver

Pribor / Nadomestni deli

Nr
Bestellnummer
Ausführung
    • Bestellnummer 52006628

      Instrument plug M20-M12 "PA" (WDM)150

      4-pin metall plug for installation in the device, providing connection to a T-Box (WDM) or cable socket (WDM). Cable length: 150mm. Not suitable for PROMAG and PROMAG.

  • 12
    • Nr 12 Bestellnummer 535720-9020

      Set of screws housing F12/T12/F23

      Consists of: 1x stop screw M5x10. 1x retaining screw M8x10. Usage: FMR230/FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44.

  • 65
    • Nr 65 Bestellnummer 52010526

      Sealing kit FMU4x

      Consists of: 1x O-ring 113.9x3.53 EPDM. 1x O-ring 72.0x3.0 EPDM. 1x O-ring 49.21x3.53 EPDM. 1x flat gasket 47x58x2 EPDM. 1x flat gasket 59x68x2.5 EPDM. 2x O-ring 17.0x2.0 EPDM. Usage: FMU40/FMU41/FMU42/ FMU43/FMU44.

  • 20
    • Nr 20 Bestellnummer 517391-0011

      Cover F12/T12 Alu, coated, gasket

      Material: aluminium, coated. O-ring EPDM. Usage: FMR230/FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44.

    • Nr 20 Bestellnummer 52005936

      Cover F12/T12 Alu, window, gasket

      Material: aluminium. Usage: VU331, housing F12/T12, Micropilot M/S, Prosonic M, Levelflex M.

  • 11
    • Nr 11 Bestellnummer 52006026

      Cover terminal compartment F12/F23

      Hood terminal compartment. Usage: Micropilot M, Prosonic M, Levelflex M.

    • Nr 11 Bestellnummer 52019062

      Cover terminal compartment F12/F23,FHX40

      Hood terminal compartment. Usage: separate display, Micropilot M, Prosonic M, Levelflex M.

  • 35
    • Nr 35 Bestellnummer 52012156

      Terminal module 4-pole, PA, FF

      PROFIBUS PA, FOUNDATION Fieldbus. Usage: Micropilot II/M, Prosonic M, Levelflex M.

    • Nr 35 Bestellnummer 52013304

      Power supply 10.5-32VDC (housing F12)

      Usage: electronics 4-wire, Levelflex M, Prosonic M.

    • Nr 35 Bestellnummer 52013305

      Power supply 90-250VAC (F12), Ex only

      Usage: electronics 4-wire, Levelflex M (Non-Ex and Ex), Prosonic M (Ex only).

    • Nr 35 Bestellnummer 52015585

      Power supply CSA, 10.5-32VDC (housg F12)

      Usage: electronics 4-wire, Levelflex M, Prosonic M.

    • Nr 35 Bestellnummer 52015586

      Power supply CSA, 90-250VAC (housg F12)

      Usage: electronics 4-wire, Levelflex M, Prosonic M.

    • Nr 35 Bestellnummer 71396869

      Power supply 90-250VAC (F12) v2, Non-Ex

      Power supply, HART, version 2. Only for "non ex area". Usage: FMU40/FMU41/FMU42/FMU43/FMU44.

  • 30
    • Nr 30 Bestellnummer 71025602

      Electronics FMU4x, Ex, 4-wire, HART,v4.0

      4-20mA, version 4.0. Usage: FMU40/FMU41/FMU42/FMU43/FMU44.

    • Nr 30 Bestellnummer 71025603

      Electronics FMU4x, Ex, PA, v4.0

      PROFIBUS PA, version 4.0. Usage: FMU40/FMU41/FMU42/FMU43/FMU44.

    • Nr 30 Bestellnummer 71025604

      Electronics FMU4x, Ex, FF, v4.0

      FOUNDATION Fieldbus, version 4.0. Usage: FMU40/FMU41/FMU42/FMU43/FMU44.

  • 40
    • Nr 40 Bestellnummer 52026443

      Display VU331, version 2

      Alphanumeric display, 4-line. Usage: FMR530/532/533, FMR540, FMU40/41/42/43/44.

    • Bestellnummer FHX40-

      Display FHX40

      Remote display + local operation. 4-line LC-display. :: Menu driven plain text operation. :: Easy setup. :: User language selectable. :: Envelope curve display on site. Usage: FMG60, FMU40/FMU41/FMU42/FMU43/FMU44.

  • 50
    • Bestellnummer 52016334

      Cable FHX40, 20m

      Connection cable, doubled shielded. Usage: FHX40.

    • Bestellnummer 942666-0000

      Mounting bracket FAU20

      Material: 316Ti. Usage: mounting FMU42/FMU43/FMU44.

    • Bestellnummer 71020502

      Cable FHX40, 5m

      Connection cable, doubled shielded. Usage: FHX40.

    • Bestellnummer 71020503

      Cable FHX40, 10m

      Connection cable, doubled shielded. Usage: FHX40.

    • Bestellnummer 71020504

      Cable FHX40, 30m

      Connection cable, doubled shielded. Usage: FHX40.

    • Bestellnummer 543199-0001

      Protective cover for housing T12/F12, SS

      Usage: Micropilot M, Micropilot S, Prosonic M, Levelflex M. Material: 316Ti.

    • Bestellnummer 71007843

      ToF Adapter FXA291

      Usage: connection Micropilot M, Micropilot S, Levelflex M, Prosonic M, Tank Side Monitor, Deltabar S, Cerabar S, Gammapilot M, Micropilot I, to Commubox FXA291.

    • Bestellnummer 71000221

      Adapterk. FMR2xx,FMx4x,PMx7x,FMD7x,FMG60

      Connection service tool RS232(52013675)/ ToF adapter FXA291 (71007843). Usage: FMG60, FMD77/FMD78, FMR230/ FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44, NRF590, PMC71, PMD75, PMP71/PMP75.

    • Bestellnummer 52013874

      Mounting bracket FHX40 1" / 2" pipe

      Usage: FHX40.

  • Predhodnik