iTEMP TMT72
Temperature transmitter

Product picture temperature transmitter iTEMP TMT72 with TID10 ©Endress+Hauser

Temperature transmitter with pluggable display TID10

Product picture temperature transmitter iTEMP TMT72 installed in field housing TA30H ©Endress+Hauser

Temperature transmitter installed in a explosion protected field housing

Product picture temperature transmitter iTEMP TMT72 ©Endress+Hauser

Transformation of sensor signals into stable and standardized output signals for all industries

Unsurpassed reliability, accuracy and long-term stability in critical processes across all industries. The configurable transmitter transfers converted signals from RTD and thermocouple (TC) temperature probes, as well as resistance and voltage signals using HART® communication. Diagnostics information according to NAMUR NE 107. Seamless integration into all major control and asset management systems. Integrated Bluetooth® interface for remote operation via Endress+Hauser SmartBlue App.

  • Benefits

    • Safe operation in hazardous areas thanks to international approvals

    • Reliable operation thanks to sensor and device monitoring

    • Integrated Bluetooth® interface for the wireless display of measured values and configuration via E+H SmartBlue (app), optional

    • Diagnostics information according to NAMUR NE 107

    • Available with plug-on display TID10

    • Optimization of...

  • Field of application

    • Bluetooth®-enabled temperature transmitter with HART® communication for the conversion of various input signals into a scalable, analog 4 to 20 mA output signal

    • Improved process efficiency and increased plant uptime

    • Universal input for RTD, TC,...

Features and specifications

Back

Details

  • Measuring principle

    Head transmitter

  • Input

    1 x RTD, TC, Ohm, mV

  • Output

    1 x analog 4...20 mA / HART

  • Auxiliary power supply

    10…36 V DC

  • Communication

    HART-protocol

    Bluetooth® technology

  • Installation

    Terminal head form B

    Field housing

  • Accuracy

    (Pt100) <= 0,07K (digital) + 0,03% (set range)

  • Galvanic isolation

    yes

  • Certification

    ATEX II1G Ex ia IIC T6

    ATEX II3G Ex ic IIC T6 Gc

    ATEX II3D Ex tc IIIC Dc

    ATEX II3G Ex nA IIC T6

    ATEX II2G Ex ia IIC T6, II3D Ex ia IIIC Dc

    ATEX II1G Ex ia IIC T6, II3D

    ATEX II3G Ex nA IIC T6, II3D

    ATEX II2G Ex db IIC T6 Gb, II2D Ex tb IIIC Db

    CSA C/US IS, NI I / 1+2/A-D

    CSA C/US XP, NI, DIP I, II, III/1+2/A-G

    IECEx Ex d T6 Gb, Ex tb IIIC Db

    ATEX IECEx II1G Ex ia IIC T6 Ga

    ATEX IECEx II2D Ex tb IIIC Db

Documents / Manuals / Software

Accessories / Spare parts

Nr
Order code
Specification
    • Order code

      The unit is not repairable

    • Order code 71044061

      Fixing kit cpl.TMT82/85/84 (european)

      2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connector

    • Order code 71044062

      Fixing kit cpl.TMT82/84/85 USA(american)

      2x screws, 1x sealing CDI-connector

    • Order code 71123339

      Set mounting bracket wall cpl. W06 std

    • Order code 71123342

      Set mounting bracket pipe housing W06 st

    • Order code 71409760

      Spare parts kit DIN rail terminal plug

      TMT82

    • Order code 71086650

      TID10 Service cable

      Extension cable for the CDI-interface for remote operation of the TID10 display for service and maintenance work Length: 40cm.

    • Order code 51000856

      DIN rail clip

      according to IEC 60715 for temperature head transmitters.

    • Order code DIENST-
    • Order code XPRFID-

      Spare RFID TAG

      Consists of: RFID TAG, fixing wire, crimp sleeve.

    • Order code FXA195-

      Commubox FXA195

      Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.

    • Order code TID10-

      Display for head transmitter TID10

      to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84, TMT82.