Deltapilot S DB50A

Product picture of: Deltapilot S DB50A

This product is no longer available.

Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.

Features and specifications

Back

Details

  • Measuring principle

    Hydrostatic

  • Characteristic / Application

    Pressure transmitter, gauge for hydrostatic level measurement, flush mounted CONTITE-sensor with metallic measuring diaphragm Alloy C4 hermetically welded + safe humidity protection
    Compact version

  • Supply / Communication

    3-wire analogue:
    15...20V DC
    2-wire PFM-Signal:
    14...16V DC
    4...20mA HART:
    11,5...30V DC
    PROFIBUS PA:
    9...24V DC
    Ex ia: 9...32V DC
    FOUNDATION Fieldbus:
    9...32V DC

  • Accuracy

    0,2%
    optional 0,1%

  • Long term stability

    0,1% of URL/6 months

  • Ambient temperature

    -40°C...85°C

  • Process temperature

    -10°C...100°C

  • Process pressure absolute / max. overpressure limit

    362,5 psi

  • Pressure measuring range

    1,5psi...150psi

  • Main wetted parts

    Alloy C
    316L

  • Process connection

    Threads
    Flanges (ASME)

  • Max. measurement distance

    100m H2O

  • Communication

    3-wire analogue
    2-wire PFM
    4 ... 20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    FM
    CSA

  • Options

    digital display
    SS-, Aluminium- or Polyesterhousing

  • Successor

    FMB70

  • Application limits

    Changing density

  • Measuring principle

    Absolute and gauge pressure

  • Characteristic

    Pressure transmitter, gauge for hydrostatic level measurement, flush mounted CONTITE-sensor with metallic measuring diaphragm Alloy C4 hermetically welded + safe humidity protection
    Compact version

  • Supply voltage

    3-wire analogue:
    15...20V DC
    2-wire PFM-Signal:
    14...16V DC
    4...20mA HART:
    11,5...30V DC
    PROFIBUS PA:
    9...24V DC
    Ex ia: 9...32V DC
    FOUNDATION Fieldbus:
    9...32V DC

  • Reference Accuracy

    0,2%
    optional 0,1%

  • Long term stability

    0,1% of URL/6 months

  • Process temperature

    -10°C...100°C

  • Ambient temperature

    -40°C...85°C

  • Measuring cell

    1,5psi...150psi

  • Max. Turn down

    max. 10:1

  • Max. overpressure limit

    362,5psi

  • Process connection

    Threads
    Flanges (ASME)

  • Communication

    3-wire analogue
    2-wire PFM
    4...20mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    FM
    CSA

  • Successor

    FMB70

Documents / Manuals / Software

Accessories / Spare parts

Nr
Order code
Specification
  • Predecessor

  • Successor