Ta izdelek ni več na voljo.
V razdelku predhodnik/naslednik preverite novo generacijo izdelka ali se obrnite na lokalnega zastopnika podjetja Endress + Hauser.
Predhodnik
-
Naslednik
-
Standardni produkti
- Zanesljivi, robustni, nezahtevni za vzdrževanje
Tehnična odličnost
Preprostost
-
Specialni produkti
- Zasnovani za posebej zahtevne aplikacije
Tehnična odličnost
Preprostost
Spremenljivo
FLEX izbira Tehnična odličnost Preprostost - F
- L
- E
- X
Segment Fundamental
Zadostite svojim osnovnim merilnim potrebam
Tehnična odličnost Preprostost - F
- L
- E
- X
Segment Lean
Obvladajte ključne procese na preprost način
Tehnična odličnost Preprostost - F
- L
- E
- X
Segment Extended
Optimirajte procese z inovativnimi tehnologijami
Tehnična odličnost Preprostost - F
- L
- E
- X
Segment Xpert
Imejte pod nadzorom najzahtevnejše aplikacije
Tehnična odličnost Preprostost Spremenljivo
-
-
Merilni princip
Coriolis
-
Product headline
The straight single‐tube flowmeter with a compact or remote transmitter. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.
-
Sensor features
Energy‐saving – full bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Straight, easy cleanable single‐tube system. TMB technology.
-
Transmitter features
Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 80 (⅜ to 3")
-
Wetted materials
Measuring tube: Titanium grade 9
Connection: Titanium grade 2 -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.15 %
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 180 000 kg/h (0 to 6600 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
–50 to +150 °C (–58 to +302 °F)
-
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
2‐line backlit display with push buttons
Configuration via local display and operating tools possible -
Outputs
3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive) -
Inputs
Status input
-
Digital communication
HART
PROFIBUS PA -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
PED, CRN
3-A -
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A
-
Merilni princip
Coriolis
-
Product headline
The straight single‐tube flowmeter with a compact or remote transmitter. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.
-
Sensor features
Energy‐saving – full bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Straight, easy cleanable single‐tube system. TMB technology.
-
Transmitter features
Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 80 (⅜ to 3")
-
Wetted materials
Measuring tube: Titanium grade 9
Connection: Titanium grade 2 -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.15 %
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 180 000 kg/h (0 to 6600 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
–50 to +150 °C (–58 to +302 °F)
-
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
2‐line backlit display with push buttons
Configuration via local display and operating tools possible -
Outputs
3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive) -
Inputs
Status input
-
Digital communication
HART
PROFIBUS PA -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
PED, CRN
3-A -
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A
-
Merilni princip
Coriolis
-
Characteristic / Application
Balanced single-tube system, "Fit-and-Forget" installation
Design:
Easy to clean, hygienic, careful handling of the medium
- chemically resistant material -
Ambient temperature
-20...+65°C
(-4...+140°F) -
Process temperature
-50...+150°C
(-58...+302°F) -
Process pressure
PN 16...100
Cl 150...600
JIS 10...63K -
Wetted parts
Titan
-
Output
4...20 mA
Pulse/Frequency
Status -
Certificates / Approvals
ATEX
FM
CSA
-
Merilni princip
Coriolis
-
Product headline
The straight single‐tube flowmeter with a compact or remote transmitter. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.
-
Sensor features
Energy‐saving – full bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Straight, easy cleanable single‐tube system. TMB technology.
-
Transmitter features
Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 80 (⅜ to 3")
-
Wetted materials
Measuring tube: Titanium grade 9
Connection: Titanium grade 2 -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.15 %
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 180 000 kg/h (0 to 6600 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
–50 to +150 °C (–58 to +302 °F)
-
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
2‐line backlit display with push buttons
Configuration via local display and operating tools possible -
Outputs
3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive) -
Inputs
Status input
-
Digital communication
HART
PROFIBUS PA -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A
-
-
Tehnične informacije (TI)
PROMASS 80/83 I/H Technical
-
Tehnične informacije (TI)
Angleška različica - 12/2005New version available in EnglishCoriolis Mass Flow Measuring System , the single-tube system with
fit-and-forget design: easy to clean hygienic minimal shear stress
on fluids.EN SL 01/12/200515/10/2003Jezik:
angleščina
Verzija:
01/12/2005
Velikost datoteke:
878.5 KB
Ime datoteke:
TI052DEN.pdf
-
-
-
Tehnične informacije (TI)
Proline Promass 80I, 83I Technical Information
-
Tehnične informacije (TI)
Angleška različica - 04/2015New version available in EnglishCombines in-line viscosity and flow measurement with
Extended Transmitter functionalityEN SL 01/04/201501/06/201025/01/201001/06/200801/12/2006Jezik:
angleščina
Verzija:
01/04/2015
Velikost datoteke:
961.7 KB
Ime datoteke:
TI00075DEN_1315.pdf
-
-
-
Navodila za uporabo (BA)
Mise en service promass - Enveloppe de réchauffement
-
Navodila za uporabo (BA)
Francoska različica - 05/2004New version available in Englishpour capteurs Promass F, M, A, I
Jezik:
French
Verzija:
28/05/2004
Velikost datoteke:
505 KB
Ime datoteke:
BA043Dfr.pdf
-
-
-
Navodila za uporabo (BA)
Proline Promass 80 PROFIBUS PA Description of Device Functions
-
Navodila za uporabo (BA)
Angleška različica - 06/2010New version available in EnglishDescription of the device functions (0ptions and inputs). Additional
documentation for Operating Instructions PROline Promass 80 PROFIBUS PA.EN SL 08/06/201001/11/200801/12/200701/12/200501/06/2001Jezik:
angleščina
Verzija:
08/06/2010
Velikost datoteke:
743 KB
Ime datoteke:
BA073DEN_0610.pdf
-
-
-
Navodila za uporabo (BA)
Proline Promass 80 PROFIBUS PA Operating Instructions
-
Navodila za uporabo (BA)
Angleška različica - 10/2012New version available in EnglishCoriolis Mass Flow Measuring System (withPROFIBUS PA interface) for
measuring the mass flow rate, density and temperature of fluids and
gases.The description of the device functions are in a separate
documentation.EN SL 15/10/201208/06/201001/11/200801/12/200701/12/2006Jezik:
angleščina
Verzija:
15/10/2012
Velikost datoteke:
2.1 MB
Ime datoteke:
BA00072DEN_1312.pdf
-
-
-
Navodila za uporabo (BA)
Proline Promass 80 HART Operating Instructions
-
Navodila za uporabo (BA)
Angleška različica - 10/2012New version available in EnglishCoriolis Mass Flow Measuring System for measuring the mass flow rate,
density and temperature of fluids and gases. The descriptionof the
device functions are in a separate documentation.EN SL 15/10/201201/03/201001/09/200801/12/200601/12/2005Jezik:
angleščina
Verzija:
15/10/2012
Velikost datoteke:
1.8 MB
Ime datoteke:
BA00057DEN_1312.pdf
-
-
-
Navodila za uporabo (BA)
Proline Promass 80
-
Navodila za uporabo (BA)
Angleška različica - 09/2008New version available in EnglishDescription of the device functions (0ptions and inputs). Additional
documentation for Operating Instructions PROline Promass 80.EN SL 01/09/200801/12/200501/11/200415/10/200301/11/2001Jezik:
angleščina
Verzija:
01/09/2008
Velikost datoteke:
1.2 MB
Ime datoteke:
BA058DEN_0908.pdf
-
-
-
Kratka navodila (KA)
Proline Promass 80 Brief Operating Instructions
-
Kratka navodila (KA)
Angleška različica - 08/2015New version available in EnglishCoriolis Mass Flow Measuring System
EN SL 06/08/201515/10/201201/07/2007Jezik:
angleščina
Verzija:
06/08/2015
Velikost datoteke:
1.3 MB
Ime datoteke:
KA00023DEN_1415.pdf
-
-
-
Navodila za vgradnjo (EA)
EA Replacing cover and O-ring
-
Navodila za vgradnjo (EA)
Angleška različica - 10/2024New version available in EnglishProline 10, 23, 50, 51, 53, 55, 400, 800, 40, 80, 83, 84, 8ME, 8FF, 8FE
,8CM, 90, 91, 92, 93, 65, 72, 73EN SL 15/10/202401/10/201828/06/2012Jezik:
angleščina
Verzija:
15/10/2024
Velikost datoteke:
797.3 KB
Ime datoteke:
EA00098DA2_1624-00.pdf
-
-
-
Navodila za vgradnjo (EA)
Replacing interface parts Installation Instructions
-
Navodila za vgradnjo (EA)
Angleška različica - 04/2019New version available in EnglishPromass 40, 80, 83, 84, Cubemass 8CN, CNGmass 8DF
EN SL 01/04/201917/11/2011Jezik:
angleščina
Verzija:
01/04/2019
Velikost datoteke:
787.5 KB
Ime datoteke:
EA00036DA2_1519.pdf
-