Innovative TempC Membrane
Highest accuracy and safety in pressure and differential pressure measurement with diaphragm seals
In processes with very high or very low temperatures, aggressive media or strong vibrations, diaphragm seals offer optimum measuring results. To measure even more precisely in such applications and to increase process safety, Endress+Hauser has developed the TempC (Temp erature C ompensatory) Membrane on basis of a completely novel technology. The patented TempC Membrane guarantees highest accuracy and increased process safety thanks to its new technology even in very demanding applications.
©Endress+Hauser
©Endress+Hauser
©Endress+Hauser
©Endress+Hauser
©Endress+Hauser
©Endress+Hauser
TempC Membrane with flanges for the process industries
TempC Membrane for hygienic applications
TempC Membrane with flanges for the process industries
TempC Membrane for hygienic applications
Increase your profitability and plant availability The very low temperature effect minimizes the influence of fluctuations of both process and ambient temperatures thus guaranteeing accurate and stable measurements. Temperature-effects on the signal are reduced to a minimum. TempC Membrane may be used in the temperature range of -40°C to +400°C. In the food and life sciences industry TempC Membrane guarantees the highest degree of process safety even for very long sterilization and cleaning cycles (CIP/SIP). Fast membrane recovery after temperature shocks of the diaphragm permits shorter downtime in batch applications and thus a significantly higher availability of production facilities. Thanks to the TempC Membrane, smaller dimension process connections are possible. The new diaphragm detects with a smaller process connection more accurate than conventional diaphragms with a larger diameter.
Following products are available with the innovative TempC Membrane:
F
L
E
X
Enostavni produkti
Lahka izbira, vgradnja in uporaba
Tehnična odličnost
Preprostost
Standardni produkti
Zanesljivi, robustni, nezahtevni za vzdrževanje
Tehnična odličnost
Preprostost
Vrhunski produkti
Visoko funkcionalni in praktični
Tehnična odličnost
Preprostost
Specialni produkti
Zasnovani za posebej zahtevne aplikacije
Tehnična odličnost
Preprostost
FLEX izbira
Tehnična odličnost
Preprostost
Segment Fundamental
Zadostite svojim osnovnim merilnim potrebam
Tehnična odličnost
Preprostost
Segment Lean
Obvladajte ključne procese na preprost način
Tehnična odličnost
Preprostost
Segment Extended
Optimirajte procese z inovativnimi tehnologijami
Tehnična odličnost
Preprostost
Segment Xpert
Imejte pod nadzorom najzahtevnejše aplikacije
Tehnična odličnost
Preprostost
New
Primerjaj
Accuracy
Standard 0.1% Platinum 0.075%
Process temperature
-40°C...+130°C (-40°F...+266°F) -20°C...+200°C (-4°F...+392°F)
Pressure measuring range
400 mbar...100 bar (6 psi...1450 psi)
Material process membrane
316L
Measuring cell
400 mbar...100 bar (6 psi...1450 psi)
Accuracy
Standard: up to 0.05 % Platinum: up to 0.025 %
Process temperature
Standard: -40°C…125°C (-40°F…257°C) Diaphragm seal: -70°C...250°C (-94°F...482°F)
Pressure measuring range
100 mbar…100 bar (1.5 psi…1500 psi) relative/ absolute
Material process membrane
316L AlloyC
Measuring cell
100 mbar…100 bar (1.5 psi…1500 psi) relative/ absolute
Accuracy
Standard: up to 0.05 % Platinum: up to 0.025 %
Process temperature
Standard: -40°C…+125°C (-40°F…+257°F) Diaphragm seal: -40°C...+400°C (-40°F...+752°F)
Pressure measuring range
400 mbar...700 bar (1.5 psi...10,500 psi)
Main wetted parts
316L, AlloyC, Tantal, Monel, PTFE, Gold
Material process membrane
316L, AlloyC, Tantal, Monel, PTFE, Gold
Measuring cell
400 mbar...700 bar (6 psi...10,500 psi)
Accuracy
Standard: up to 0.075 %
Process temperature
-70°C...+250°C (-94°F...+482°F)
Pressure measuring range
100 mbar...40 bar (1.5 psi...600 psi)
Main wetted parts
316L
Material process membrane
316L
Measuring cell
100 mbar...40 bar (1.5 psi...600 psi)
Accuracy
Standard: up to 0.075 % Platinum up to 0.055 %
Process temperature
Standard: -40°C…+125°C (-40°F…+257°F) Diaphragm seal: -40°C...+400°C (-40°F...+752°F)
Pressure measuring range
400 mbar... 400 bar (6psi...6,000psi)
Main wetted parts
316L, AlloyC, Tantal, Monel, PTFE
Material process membrane
316L, AlloyC, Tantal, Monel, PTFE
Measuring cell
400 mbar...400 bar (6psi...6,000psi)
Accuracy
Standard: up to 0.065 % Platinum: up to 0.055 %
Process temperature
Standard: -40°C…+125°C (-40°F...+257°F) Diaphragm seal: -70°C...+400°C (-94°F...+752°F)
Material process membrane
316L, AlloyC, Gold
Measuring cell
1 bar...400 bar (14.5 psi...5800 psi)
Accuracy
Standard: up to 0.1 %
Process temperature
-40°C...+400°C (-40°F...+752°F)
Pressure measuring range
100 mbar...40 bar (1.5psi...600 psi)
Main wetted parts
316L, AlloyC, Tantal, Monel PTFE, Gold
Material process membrane
316L, AlloyC, Tantal, Monel PTFE Gold
Measuring cell
100 mbar...40 bar (1.5 psi...600 psi)
Postopno ukinjanje - Prikaži naslednike
Nazaj
Izdelek se postopoma ukinja
Na voljo nove alternative
Smernice za postopno opuščanje
Endress+Hauser se zavezuje k dolgoročni podpori vseh naših izdelkov.
Prevzemamo podporo in servis naših izdelkov za obdobje desetih let po obvestilu o umiku izdelka (do trenutka, ko nadomestni deli niso več na voljo).
Vendar si pridržujemo pravico do ponudbe alternativnih rešitev, vključno z nadomestnimi izdelki, če se štejejo za bolj primerne.
Status izdelka
Koren izdelka
PMP55
Ime
Absolute and
gauge pressure
Cerabar PMP55
Status izdelka
In phase out
Datum ukinitve
12/2024
Ustavitev naročila
6/2027
Nadomestni senzor do
not applicable
Kalibracija do
not applicable
Razpoložljivost rezervnih delov
7/2030
Popravilo do
7/2030
Nasveti za vzdrževanje
Primerjaj
Accuracy
Standard 0.15% Platinum 0.075%
Process temperature
-70°C…400°C (-94°F…752°F)
Pressure measuring range
1 bar...400 bar (15 psi...6000 psi)
Process pressure / max. overpressure limit
600 bar (9000 psi)
Main wetted parts
316L AlloyC Montel Tantal Rhodium
Max. measurement distance
4000m (13.123ft) H2O
Material process membrane
316L, AlloyC, Tantal, PTFE, Rhodium>Gold
Measuring cell
400 mbar...400 bar (5.8 psi...6000 psi) relative/ absolute
Postopno ukinjanje - Prikaži naslednike
Nazaj
Izdelek se postopoma ukinja
Na voljo nove alternative
Smernice za postopno opuščanje
Endress+Hauser se zavezuje k dolgoročni podpori vseh naših izdelkov.
Prevzemamo podporo in servis naših izdelkov za obdobje desetih let po obvestilu o umiku izdelka (do trenutka, ko nadomestni deli niso več na voljo).
Vendar si pridržujemo pravico do ponudbe alternativnih rešitev, vključno z nadomestnimi izdelki, če se štejejo za bolj primerne.
Status izdelka
Koren izdelka
PMP75
Ime
Absolute and
gauge pressure
Cerabar PMP75
Status izdelka
In phase out
Datum ukinitve
12/2024
Ustavitev naročila
6/2027
Nadomestni senzor do
not applicable
Kalibracija do
not applicable
Razpoložljivost rezervnih delov
7/2030
Popravilo do
7/2030
Nasveti za vzdrževanje
Primerjaj
Accuracy
0,075% + influence of diaphragm seal
Process temperature
-70°C...400°C (-94°F...752°F)
Pressure measuring range
400 mbar...400 bar (5.8 psi...6000 psi)
Process pressure / max. overpressure limit
1050bar (15,200psi)
Main wetted parts
Alloy C276 316L Monel Tantalum PTFE-Foil
Max. measurement distance
7000m (22.966ft) H2O
Material process membrane
316L AlloyC
Measuring cell
100 mbar…100 bar (1.5 psi…1500 psi) relative/ absolute
Postopno ukinjanje - Prikaži naslednike
Nazaj
Izdelek se postopoma ukinja
Na voljo nove alternative
Smernice za postopno opuščanje
Endress+Hauser se zavezuje k dolgoročni podpori vseh naših izdelkov.
Prevzemamo podporo in servis naših izdelkov za obdobje desetih let po obvestilu o umiku izdelka (do trenutka, ko nadomestni deli niso več na voljo).
Vendar si pridržujemo pravico do ponudbe alternativnih rešitev, vključno z nadomestnimi izdelki, če se štejejo za bolj primerne.
Status izdelka
Koren izdelka
FMD78
Ime
Differential pressure
Deltabar FMD78
Status izdelka
In phase out
Datum ukinitve
12/2024
Ustavitev naročila
6/2027
Nadomestni senzor do
not applicable
Kalibracija do
not applicable
Razpoložljivost rezervnih delov
7/2030
Popravilo do
7/2030
Nasveti za vzdrževanje
Primerjaj
Accuracy
0,075% + influence of diaphragm seal
Process temperature
-40°C...400°C (-40°F...752°F)
Pressure measuring range
100mbar...40bar (1.5psi ... 600 psi)
Process pressure / max. overpressure limit
160bar (2400 psi)
Main wetted parts
Alloy C276 316L Monel Tantalum
Max. measurement distance
400m (1312ft) H2O
Material process membrane
316L, AlloyC, Tantal, Gold-Rhodium PTFE
Measuring cell
100 mbar...40 bar (40 inH2O...600 psi)
Cenimo vašo zasebnost
Uporabljamo piškotke, da bi lahko izboljšali vašo izkušnjo med brskanjem, zbirali statistične podatke za izboljšanje delovanja spletnega mesta in zagotavljali prilagojene oglase ali vsebine.
Z izbiro "Sprejmi vse" se strinjate z našo uporabo piškotkov.
Za podrobnosti si oglejte naš Pravilnik o piškotkih .
Prilagodi
Sprejmi samo bistveno
Sprejmi vse