  • Merilni princip

    Radiometric

  • Characteristic / Application

    Source container
    Emission angle: 40 / 20 degrees
    Approximately 40kg

  • Specialities

    Manual or pneumatic switch-on/ switch-off

  • Ambient temperature

    -40 °C...+200 °C
    (-40 °F...+392 °F)

  • Process temperature

    Any

  • Process pressure / max. overpressure limit

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Certificates / Approvals

    ATEX, GOST

  • Merilni princip

    Radiometric

  • Characteristic / Application

    Source container
    Emission angle: 40 / 20 degrees
    Approximately 40kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    -40 °C...+200 °C
    (-40 °F...+392 °F)

  • Process temperature

    Any

  • Process pressure / max. overpressure limit

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Certificates / Approvals

    ATEX, GOST

  • Merilni princip

    Radiometric Limit

  • Characteristic / Application

    Source container
    Emission angle: 5 degrees
    Approximately 40kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    -40 °C...+200 °C
    (-40 °F...+392 °F)

  • Process temperature

    Any

  • Process pressure / max. overpressure limit

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Certificates / Approvals

    ATEX, GOST

  • Merilni princip

    Radiometric Limit

  • Characteristic / Application

    Source container
    Emission angle: 5 degrees
    Approximately 40kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    -40 °C...+200 °C
    (-40 °F...+392 °F)

  • Process temperature

    Any

  • Process pressure / max. overpressure limit

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Certificates / Approvals

    ATEX, GOST

  • Merilni princip

    Radiometric Density

  • Characteristic / Application

    Source container
    Emission angle: 5/ 20/ 40 degrees
    Approximately 40kg

  • Ambient temperature

    -40 °C...+200 °C
    (-40 °F...+392 °F)

  • Process temperature

    Any

  • Process pressure

    Any

  • Wetted parts

    Non-contact

  • Hygienic

    Non-contact

  • Specialities

    Control area calculation with Applicator