Lastnosti na dlani
-
Sampling probe compatibility
Raman Rxn-10 probe
Področje uporabe
Developed according to industry standards for single-use sensors, this Raman optic system is cGMP qualified and gamma sterilizable. The system is comprised of two parts - a reusable optic and a disposable fitting for single-use bioreactors (SUB). The Raman optic system for single use in conjunction with the Rxn-10 probe offers the same quality data as reusable Raman probes. This ability allows customers to develop products and processes without limitations of the final production reactor type.
Cell culture: glucose, lactate, amino acids, cell density, titer
Fermentation: glycerol, methanol, ethanol, sorbitol, biomass
Prednosti
Disposable fitting for single-use bioreactors (SUB), plus a non-contact reusable optic
Developed to industry standards for single-use sensors
Gamma sterilizable
Tested and supplied by multiple SUB vendors
Segment Xpert
-
Specialni produkti
- Zasnovani za posebej zahtevne aplikacije
Tehnična odličnost
Preprostost
Spremenljivo
-
Standardni produkti
- Zanesljivi, robustni, nezahtevni za vzdrževanje
Tehnična odličnost
Preprostost
-
Specialni produkti
- Zasnovani za posebej zahtevne aplikacije
Tehnična odličnost
Preprostost
Spremenljivo
FLEX izbira | Tehnična odličnost | Preprostost |
---|---|---|
Segment Fundamental Zadostite svojim osnovnim merilnim potrebam |
Tehnična odličnost
|
Preprostost
|
Segment Lean Obvladajte ključne procese na preprost način |
Tehnična odličnost
|
Preprostost
|
Segment Extended Optimirajte procese z inovativnimi tehnologijami |
Tehnična odličnost
|
Preprostost
|
Segment Xpert Imejte pod nadzorom najzahtevnejše aplikacije |
Tehnična odličnost
|
Preprostost
Spremenljivo |
-
-
Tehnične informacije (TI)
Accessory Optics for the Rxn-10 Probe Technical Information
System design and specifications for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)EN SL 31/05/202303/08/2022Jezik:
angleščina
Verzija:
31/05/2023
Velikost datoteke:
467.9 KB
Ime datoteke:
TI01635CEN_0322.pdf
-
-
-
Tehnične informacije (TI)
Rxn-10 Raman Spectroscopic Probe Technical Information
System design and specifications
for the Raman Rxn-10 probeJezik:
angleščina
Verzija:
31/05/2023
Velikost datoteke:
423 KB
Ime datoteke:
TI01629CEN_0322.pdf
-
-
-
Navodila za uporabo (BA)
Accessory optics for the Rxn-10 Probe Operating Instructions
Commissioning, operation, and maintenance details
for Rxn-10 probe optics: Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)EN SL 31/05/202303/08/2022Jezik:
angleščina
Verzija:
31/05/2023
Velikost datoteke:
1.8 MB
Ime datoteke:
BA02171CEN_0322.pdf
-
-
-
Navodila za uporabo (BA)
Rxn-10 Raman Spectroscopic Probe Operating Instructions
Commissioning, operation, and maintenance details
for the Raman Rxn-10 probeJezik:
angleščina
Verzija:
31/05/2023
Velikost datoteke:
1.2 MB
Ime datoteke:
BA02160CEN_0322.pdf
-
-
-
Kratka navodila (KA)
Rxn-10 Raman Spectroscopic Probe Brief Operating Instructions
Quick start guide for the Raman Rxn-10 probe
Jezik:
angleščina
Verzija:
31/05/2023
Velikost datoteke:
895.3 KB
Ime datoteke:
KA01546CEN_0322.pdf
-
-
-
Kratka navodila (KA)
Accessory Optics for the Rxn-10 Probe Brief Operating Instructions
Quickstart guide for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)EN SL 31/05/202303/08/2022Jezik:
angleščina
Verzija:
31/05/2023
Velikost datoteke:
1 MB
Ime datoteke:
KA01551CEN_0322.pdf
-
-
-
PU (objava)
Raman application guide for the life science industry - Trusted composition analysis for the life sciences
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).Jezik:
angleščina
Verzija:
19/04/2022
Velikost datoteke:
1.1 MB
Ime datoteke:
PU01447CEN_0222.pdf
-
-
-
PU (objava)
Lab-to-process monitoring & control in Life Sciences - Reliable measurement of bioprocess physical and chemical properties
A combined product list of analysis offerings from both Optical Analysis
and Liquid Analysis for bioprocessing applications in the life science
industry (including Raman Rxn2 analyzer, Raman Rxn4 analyzer,
Rxn-10 probe, bIO-Optic, Rxn-45 probe, Rxn-46 probe, Raman optic
system for single use, Memosens CPS61E, Memosens COS81E, OUSBT66,
Memosens CPS61E, Memosens CPS77E, Memosens CLS82E, OUSAF44,
Memosens CPS11E, Memosens CLS16E, TOC Analyzer CA79, Liquiline
transmitter platform, and Memobase software).Jezik:
angleščina
Verzija:
10/08/2022
Velikost datoteke:
782.3 KB
Ime datoteke:
PU01484CEN_0122.pdf
-
-
-
PU (objava)
Raman calibration and verification kits - Everything needed to calibrate and verify your Raman analyzer system for lab-to-process scalability
An overview of the Raman calibration and verification kits for
the bio multi optic / single use optic and the Raman flow assembly
(includes the flow bench and flow cell). These kits are to be used in
conjunction with the Rxn-10 probe and Raman Rxn2 / Rxn4 analyzer
for upstream and downstream bioprocessing (powered by Kaiser
Raman technology).Jezik:
angleščina
Verzija:
13/12/2023
Velikost datoteke:
2.1 MB
Ime datoteke:
PU01518CEN_0223.pdf
-
-
-
Inovacija (IN)
Raman technology in bioprocessing - Scalable in situ bioprocess monitoring enabling advanced process control
An overview brochure about our Raman spectroscopy analyzer
and probe portfolio, powered by Kaiser Raman technology, for
the bioprocessing / biopharmaceutical industry (including the
Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe,
Rxn-45 probe, Rxn-46 probe, and probe accessory optics (bIO-Optic,
Raman single use optic system, bio multi optic with bio sleeve, and
Raman flow assembly), powered by Kaiser Raman technology.Jezik:
angleščina
Verzija:
19/06/2023
Velikost datoteke:
6.8 MB
Ime datoteke:
IN01228CEN_0223.pdf
-