Za začetek iskanja vnesite vsaj dva znaka.
  • Zgodovina

Conductive
Point level detection
One rod probe 11961Z

Probe 11961Z ©Endress+Hauser

High resistance point level detection of conductive liquids steam boilers and aggressive media

The 11961Z is a highly resistant probe for applications with aggressive medium thanks to corrosion-resistant materials for rod and insulation. It can be used in steam boilers thanks to ceramic insulation resistant to steam and hot water.

  • Enostavni produkti

  • Lahka izbira, vgradnja in uporaba

Tehnična odličnost

Preprostost

  • Standardni produkti

  • Zanesljivi, robustni, nezahtevni za vzdrževanje

Tehnična odličnost

Preprostost

  • Vrhunski produkti

  • Visoko funkcionalni in praktični

Tehnična odličnost

Preprostost

  • Specialni produkti

  • Zasnovani za posebej zahtevne aplikacije

Tehnična odličnost

Preprostost

Spremenljivo

FLEX izbira Tehnična odličnost Preprostost
  • F
  • L
  • E
  • X

Segment Fundamental

Zadostite svojim osnovnim merilnim potrebam

Tehnična odličnost
Preprostost
  • F
  • L
  • E
  • X

Segment Lean

Obvladajte ključne procese na preprost način

Tehnična odličnost
Preprostost
  • F
  • L
  • E
  • X

Segment Extended

Optimirajte procese z inovativnimi tehnologijami

Tehnična odličnost
Preprostost
  • F
  • L
  • E
  • X

Segment Xpert

Imejte pod nadzorom najzahtevnejše aplikacije

Tehnična odličnost
Preprostost

Spremenljivo

  • Lastnosti na dlani

    • Process temperature

      -200 °C ... 250 °C
      (-328 °F ... 482 °F)

    • Process pressure absolute / max. overpressure limit

      Vacuum ... 160 bar
      (Vacuum ... 2320 psi)

    • Min. conductivity of medium

      20 µS/cm

please wait Loading alternative products

Hitra izbira

Izberite med predlaganimi možnostmi
Prodajna cena
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

ali

Individualna konfiguracija

Nadaljujte z izbiranjem med vsemi možnostmi
  • Prednosti

    • Safe and reliable measurement even in aggressive medium thanks to corrosion-resistant materials for rod and insulation

    • Can be used in steam boilers thanks to ceramic insulation resistant to steam and hot water

    • Can be deployed particularly with high...

  • Področje uporabe

    For conductive point level detection in process or storage tanks, for conductivity as of 0.02mS/cm. As overfill prevention with line monitoring even in Ex-area Zone 0, or pump protection in pipes and two-point control.

    • Process connection: Thread

    • ...

Lastnosti in specifikacije

Nazaj

Podrobnosti

  • Merilni princip

    Conductive

  • Characteristic / Application

    One rod probe for high and extremely low temperature and high pressure. Corrosion resistant

  • Supply / Communication

    Relay
    PFM

  • Ambient temperature

    -200 °C ... 250 °C
    (-328 °F ... 482 °F)

  • Process temperature

    -200 °C ... 250 °C
    (-328 °F ... 482 °F)

  • Process pressure absolute / max. overpressure limit

    Vacuum ... 160 bar
    (Vacuum ... 2320 psi)

  • Min. conductivity of medium

    20 µS/cm

  • Main wetted parts

    Ceramic, 316TI

  • Process connection

    G 1/2

  • Sensor length

    0.1m ... 2m
    (3.9" ... 79")

  • Communication

    Relay

  • Components

    Transmitter: FTW325

  • Application limits

    Observe min. medium conductivity

Dokumenti / Priročniki / Softver

Pribor / Nadomestni deli

Št.
Kataloška koda
Specifikacija
  • Predhodnik