Lastnosti na dlani
-
Measurement range
pH 0-14
-
Process temperature
max. 110°C
(230°F) -
Process pressure
max. 10 bar
(145 psi)
Področje uporabe
Memosens CPS96D is the expert for fibrous media or media with a high content of suspended solids such as dispersions, precipitation or emulsions. The open aperture guarantees the most reliable, simultaneous pH and ORP measurement for better process control and increased quality. Memosens CPS96D is not the latest Memosens generation. To get information on the new Memosens CPS96E sensor with extended functionality, click here.
Chemical processes
Pulp and paper industry
Contaminated media and suspended solids
- Dispersions
- Precipitation
- Emulsions
With ATEX and IEC approval for use in hazardous areas.
Prednosti
Simultaneous measurement of pH, ORP and rH values (in rH mode) for a better process overview
Additional platinum electrode enables constant monitoring of reference impedance and thus sensor quality
Robust and resistant to poisoning thanks to stabilized gel and reference with ion trap
Not affected by fluctuations in pressure and temperature
Maximum process safety through non-contact inductive signal transmission
Enables predictive maintenance due to storage of sensor and process-specific data
Reduced operating costs due to minimized process downtime and extended sensor lifetime
Videoposnetki
Segment Extended
-
Vrhunski produkti
- Visoko funkcionalni in praktični
Tehnična odličnost
Preprostost
-
Standardni produkti
- Zanesljivi, robustni, nezahtevni za vzdrževanje
Tehnična odličnost
Preprostost
-
Specialni produkti
- Zasnovani za posebej zahtevne aplikacije
Tehnična odličnost
Preprostost
Spremenljivo
FLEX izbira | Tehnična odličnost | Preprostost |
---|---|---|
Segment Fundamental Zadostite svojim osnovnim merilnim potrebam |
Tehnična odličnost
|
Preprostost
|
Segment Lean Obvladajte ključne procese na preprost način |
Tehnična odličnost
|
Preprostost
|
Segment Extended Optimirajte procese z inovativnimi tehnologijami |
Tehnična odličnost
|
Preprostost
|
Segment Xpert Imejte pod nadzorom najzahtevnejše aplikacije |
Tehnična odličnost
|
Preprostost
Spremenljivo |
-
-
Tehnične informacije (TI)
Memosens CPS96D Technical Information
Combination of pH and ORP electrode with Memosens technology
EN SL 30/11/201402/05/2012Jezik:
angleščina
Verzija:
30/11/2014
Velikost datoteke:
404.1 KB
Ime datoteke:
TI00507CEN_0214.pdf
-
-
-
Navodila za uporabo (BA)
Memosens CPS16D/76D/96D Operating Instructions
Combined pH and ORP electrodes with Memosens technology
Kombination aus pH- und Redoxelektrode mit Memosens-TechnologieEN SL 31/01/201822/05/2012Jezik:
angleščina
Verzija:
31/01/2018
Velikost datoteke:
697 KB
Ime datoteke:
BA01109CA2_0218.pdf
-
-
-
Ex varnostna navodila (XA)
Memosens pH/ORP Sicherheitshinweise für elektrische Betriebsmittel im explosionsgefährdeten Bereich Safetyinstructions for electrical apparatus for explosion-hazardous areas Conseils de sécurité pour matériels électriques destinés aux zones explosibles Safety Instructions
Safety instructions for electrical apparatus for explosion-hazardous
areasEN SL 11/11/201631/12/201101/04/2009Jezik:
angleščina
Verzija:
11/11/2016
Velikost datoteke:
3.7 MB
Ime datoteke:
XA00079CA3_1416.pdf
-
-
-
Ex varnostna navodila (XA)
Memosens pH/ORP Sicherheitshinweise für elektrische Betriebsmittel im explosionsgefährdeten Bereich Safetyinstructions for electrical apparatus for explosion-hazardous areas Conseils de sécurité pour matériels électriques destinés aux zones explosibles Safety Instructions
Safety instructions for electrical apparatus for explosion-hazardous
areasEN SL 22/02/201604/03/201514/01/201321/10/201001/12/2006Jezik:
angleščina
Verzija:
22/02/2016
Velikost datoteke:
4.3 MB
Ime datoteke:
XA00376CA3_1616.pdf
-
-
-
Ex varnostna navodila (XA)
Memosens ph/ORP sensors
pH/ORP measurement
Supplement to BA01572C, BA01109C
Safety instructions for electrical apparatus in explosion-hazardous
areas
UKEx II 1 G Ex ia IIC T3/T4/T6 Ga
UK Ex II 1 G Ex ia IIC T4/T6 GaJezik:
angleščina
Verzija:
08/12/2021
Velikost datoteke:
435.2 KB
Ime datoteke:
XA02786CEN_0121-00.pdf
-
-
-
Ex varnostna navodila (XA)
Memosens pH/ORP sensors
pH and ORP measurement
Supplement to: BA01572C, BA01109C
Safety instructions for electrical equipment in explosion-hazardous
areas
EAC Ex 0Ex ia IIC T3/T4/T6 Ga X
EAC Ex 0Ex iaIIC T4/T6 Ga XEN SL 01/03/202218/02/202108/03/2016Jezik:
angleščina
Verzija:
01/03/2022
Velikost datoteke:
508.1 KB
Ime datoteke:
XA01437CEN_0322-00.pdf
-
-
-
Informativni dokument (WP)
Damit bei der pH-Messung höchste Genauigkeit garantiert ist
Kalibrierung,Justierung und Verifizierung
Jezik:
nemščina
Verzija:
07/04/2021
Velikost datoteke:
605.2 KB
Ime datoteke:
WP01154C07DE_01.21_Damit bei der pH-Messung hoechste Genauigkeit garantiert ist.pdf
-
-
-
Informativni dokument (WP)
Ensuring maximum accuracy in pH measurement
Calibration, adjustment and verification
Jezik:
angleščina
Verzija:
07/04/2021
Velikost datoteke:
600 KB
Ime datoteke:
WP01154C07EN_01.21_Ensuring maximum accuracy in pH measurement.pdf
-
-
-
Izjava EU
Product family: CeraGel, CeraLiquid, Memosens, OrbiPore, OrbiSint
Product root: CPS11D-, CPS12D-, CPS16D-, CPS41D-, CPS42D-,
CPS71D-, CPS72D-, CPS76D-, CPS91D-, CPS92D-, CPS96D-
Declaration number: EC_00385_02.16EN SL 22/07/2017Jezik:
angleščina
Verzija:
22/07/2017
Velikost datoteke:
556.7 KB
Ime datoteke:
EC_00385_02.16.pdf
-
-
-
Izjava EU
Product family: CeraGel, CeraLiquid, Ceramax, ConduMax H, ConduMax W, InduMax H, InduMax P, Liquiline, Memosens, Messkabel, Orbi Pac, OrbiPore, OrbiSint, OxyMax H, OxyMax W, TopHit
Product root: CLS15D-, CLS16D-, CLS21D-, CLS50D-, CLS54D-, CLS82D-,
CML18-, COS21D-, COS22D-, COS51D-, COS81D-, CPF82D-, CPL51E-
,
CPS11D-, CPS12D-, CPS16D-, CPS171D-, CPS31D-, CPS341D-, CPS41D-,
CPS42D-, CPS441D-, CPS471D-, CPS47D-, CPS491D-, CPS71D-,
CPS72D-,
CPS77D-, CPS91D-, CPS92D-, CPS96D-, CPS97D-, CYK10-, CYK20-
Declaration number: EC_00828_02.20EN SL 14/02/2022Jezik:
angleščina
Verzija:
14/02/2022
Velikost datoteke:
281.9 KB
Ime datoteke:
EC_00828_03.22_D-Sensoren CML18 EMV_RoHS.pdf
-