Digital pressure transmitter with fully welded diaphragm seal for measurement in gases or liquids

The Cerabar PMP75 digital pressure transmitter with metal diaphragm seal is typically used in process and hygiene applications for pressure, level, volume or mass measurement in liquids or gases. Suitable for high pressure as well as extreme process temperature applications from -70 up to +400°C (-94 to 750°F). Quick Setup with adjustable measuring range allows simple commissioning, reduces costs and saves time. Designed according to IEC 61508 for use in SIL2/3 safety applications.

Hitra izbira

Izberite med predlaganimi možnostmi
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

or

Individualna konfiguracija

Nadaljujte z izbiranjem med vsemi možnostmi
  • Prednosti

    • Large variety of different process connections and membrane materials

    • New TempC Membrane minimizes influences of ambient and process temperature fluctuations

    • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics

    • Easy...

  • Področje uporabe

    Two chamber aluminum or stainless steel (316L) housing.

    • Process connections: Threads, flanges or hygienic connections

    • Process temperature: -70 to +400°C (-94 to +752°F)

    • Pressure: -1/0 up to 400bar (-15/0 up to +6,000psi)

    • Accuracy: ±0.075%

    • ...

Details

  • [h5] TEST

    Absolute and gauge pressure

  • Characteristic / Application

    Digital transmitter with piezoresistive sensor and diaphragm seal
    Modular transmitter
    Long term stability
    Minimum oil volume
    Enhanced safety via self diagnostic functions
    Secondary process barrier

  • Specialities

    Diagnostic functionalities

    Different languages in software

  • Supply / Communication

    4...20mA HART:
    10,5...45V DC
    Ex ia: 10,5...30V DC
    PROFIBUS PA /
    FOUNDATION Fieldbus:
    9...32V DC

  • Accuracy

    0,075% + influence of diaphragm seal

  • Long term stability

    0,05% of URL/year

  • Ambient temperature

    -50°C...85°C
    (-58°F...185°F)

  • Process temperature

    -70°C...400°C
    (-94°F...752°F)

  • Process pressure absolute / max. overpressure limit

    1050bar (15,200psi)

  • Pressure measuring range

    400 mbar...400 bar
    (6 psi...6000 psi)

  • Main wetted parts

    Alloy C276
    316L
    Monel
    Tantalum
    PTFE-Foil

  • Process connection

    Threads
    Flanges (DIN, ASME, JIS) with flush membrane
    Tri-Clamp ISO02852
    Hygienic connections

  • Max. measurement distance

    7000m (22.966ft) H2O

  • Communication

    4...20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC

  • Safety approvals

    Overfill prevention WHG

    SIL

  • Design approvals

    EN 10204-3.1

    NACE MR0175, MR0103

  • Hygienic approvals

    3A, EHEDG

  • Marine approval

    GL/ ABS

  • Options

    HistoROM/M-Dat
    4-line digital display
    SS- or Aluminiumhousing
    Separate housing

  • Application limits

    Measuring cell: Metal
    welded

    If pressurized, possibly
    use differential pressure
    meas-urement with two
    pressure transmitters
    (electronic dp). Observe
    ratio head pressure :
    hydrostatic pressure

  • [h5] TEST

    Absolute and gauge pressure

  • Characteristic

    Digital transmitter with piezoresistive sensor and diaphragm seal
    Modular transmitter
    Long term stability
    Minimum oil volume process connection
    Enhanced safety via self diagnostic functions
    Secondary process barrier

  • Supply voltage

    4...20 mA HART

    10,5...45V DC (Non Ex):

    Ex ia: 10,5...30V DC

    PROFIBUS PA:

    9...32 V DC (Non Ex)

    FOUNDATION Fieldbus:

    9...32 V DC (Non Ex)

  • Reference Accuracy

    0,075% + influence of diaphragm seal

  • Long term stability

    0.05 % of URL/ year

    0.07 % of URL/ 5 years

    0.1 % of URL/ 10 years

  • Process temperature

    -70°C...400°C
    (-94°F...752°F)

  • Ambient temperature

    -50°C...85°C
    (-58°F...185°F)

  • Measuring cell

    400 mbar...400 bar
    (6 psi...6000 psi)

    relative/ absolute

  • Smallest calibratable span

    5 mbar (0.075 psi)

  • Vacuum resistance

    10 mbar (0.15 psi)

  • Max. Turn down

    100:1

  • Max. overpressure limit

    1050 bar (15.750 psi)

  • Process connection

    Thread:

    G1/2...G2, R1/2, MNPT1/2...MNPT2, NPT1/2...NPT1

    Flange:

    DN25...DN100,

    ASME 1"...4",

    JIS 10K

    Diaphragm seal

  • Process connection hygienic

    Tri-Clamp

    DIN11851

    NEUMO

    Varivent

    SMS

    DRD

    Universal adapter

  • Material process membrane

    316L, AlloyC,

    Tantal

    Rhodium> Gold

    PTFE

  • Material gasket

    None, diaphragm welded

  • Fill fluid

    Silicone oil,

    Inert oil,

    Vegetable oil,

    High temperature oil,

    Low temperature oil,

  • Material housing

    Die-cast aluminum,

    AISI 316L

  • Communication

    4...20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC

  • Safety approvals

    Overfill prevention WHG

    SIL

  • Design approvals

    EN10204-3.1

    NACE MR0103

  • Hygienic approvals

    3A, EHEDG

  • Marine approvals

    GL/ ABS

  • Specialities

    Diagnostic functions

    TempC Membrane

Dokumenti / Priročniki / Softver

Pribor / Nadomestni deli

Nr
Bestellnummer
Ausführung
  • 13
    • Nr 13 Bestellnummer 52022418

      Push button housing, PA/FF

      Consists of: push button, cover + screws. Usage: external operation, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 13 Bestellnummer 52022419

      Push button housing, HART, version 1

      Consists of: push button, cover + screws. Colour light grey. Usage: external operation, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 13 Bestellnummer 52024110

      Push button housing, HART, version 2

      Consists of: push button, cover + screws. Colour dark grey. Usage: external operation, FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75.

  • 15
    • Nr 15 Bestellnummer 52020760

      Cable gland M20, gasket

      Consists of: cable gland M20. O-ring 18.72x2.62 VMQ. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 15 Bestellnummer 52020761

      Cable entry G1/2, gasket, adapter

      Consists of: gasket 18.72x2.51 NBR. Adapter M20 > G1/2. O-ring 18.77x1.78 NBR. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 15 Bestellnummer 52020762

      Plug 2/7-pole, HAN7D, gasket

      Consists of: harting plug set. Usage: FMB50/FMB51/FMB52/FMB53, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD55, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Nr 15 Bestellnummer 52020763

      Plug 3-pole, M12, gasket

      Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Bestellnummer 71111056

      Housing filter VA,EPDM,F15/31/T14/17,1pc

      Consists of: vent screw 304. Pressure compensation filter. O-ring EPDM, protection lid. Usage: housing T14, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Housing F31, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55. Housing F15 w/o B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.

    • Bestellnummer 71219639

      Housing filter VA, VMQ, F15, T17, 1 pc.

      Consists of: vent screw 304. Pressure compensation filter. O-ring VMQ, protection lid. Usage: housing T17, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/ PMP75. Housing F15 bei B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.

  • 20
    • Nr 20 Bestellnummer 52020432

      Cover T14/T15 Alu, gasket

      Material: aluminium, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Bestellnummer 52020433

      Cover T14/T15 Alu, Ex d, gasket

      Material: aluminium, coated. O-ring EPDM, FDA. EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Bestellnummer 52028310

      Cover T14 316L, Ex d, EPDM

      Material: 316L. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Bestellnummer 71002774

      Cover T17 316L, gasket

      Material: 316L. Flat gasket EPDM, centering ring, screw. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Bestellnummer 71002810

      Cover T17 316L, sight glass, gasket

      Material: 316L. Sight glass: mineral glass. Flat gasket EPDM, centering ring, screw. For approval 2,3,4,7,8,Q,W. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. For approval BC,BD,IB. Usage: FMD71/FMD72.

    • Nr 20 Bestellnummer 71002811

      Cover T17 316L, sight glass PC, gasket

      Material: 316L. Sight glass: Polycarbonate PC. Flat gasket EPDM, centering ring, screw. For approval A,E,F,H,I,R,S,U,1,6. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. For approval AA,BA,CA,CB,CC,CD,FA,FB, FD,IA. Usage: FMD71/FMD72.

    • Nr 20 Bestellnummer 71206965

      Cover T14 316L, Ex d, FVMQ

      Material: 316L. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75.

    • Nr 20 Bestellnummer 71206968

      Cover T14 316L, Ex d, sight glass, FVMQ

      Material: 316L. Sight glass: mineral glass,coated. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Bestellnummer 71245247

      Cover T14/T15 Alu, sight glass, gasket

      Material: aluminium, coated. Sight glass: mineral glass, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Bestellnummer 71245249

      Cover T14/T15 Alu,Exd,sight glass,gasket

      Material: aluminium. Sight glass mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Bestellnummer 71245250

      Cover T14 316L, Ex d, sight glass, EPDM

      Material: 316L. Sight glass: mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 21
    • Nr 21 Bestellnummer 52020429

      Sealing EPDM, F30/31/34, T14/15, 5 pcs.

      Consists of: 5x O-ring 75.87x2.62, EPDM, PTFE, FDA. Usage: housing F30/F31/F34, T14/T15.

    • Nr 21 Bestellnummer 71206971

      Sealing set FVQM, T14.5 pcs.

      Consists of: 5x O-ring 75.87x2.62 FVMQ. Usage: housing T14, FMD77/FMD78, PMD70/PMD75, PMP71/PMP75.

    • Bestellnummer 71290825

      Ground terminal T14/T15/T17, F30/F31

      Consists of: spring washer, screw, earth handle, clamp. Usage: housing T14/T15/T17, FMB70, FMD71/FMD72/ FMD77/FMD78, PMC71, PMP71/PMP75, PMD70/PMD75. Housing F30/F31, FMB50/FMB51/FMB52/ FMB53, PMC51, PMD55, PMP51/PMP55.

  • 25
    • Nr 25 Bestellnummer 52020432

      Cover T14/T15 Alu, gasket

      Material: aluminium, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 25 Bestellnummer 52020433

      Cover T14/T15 Alu, Ex d, gasket

      Material: aluminium, coated. O-ring EPDM, FDA. EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 25 Bestellnummer 52028310

      Cover T14 316L, Ex d, EPDM

      Material: 316L. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 25 Bestellnummer 71002774

      Cover T17 316L, gasket

      Material: 316L. Flat gasket EPDM, centering ring, screw. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 25 Bestellnummer 71206965

      Cover T14 316L, Ex d, FVMQ

      Material: 316L. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75.

  • 30
    • Nr 30 Bestellnummer 52024111

      Electronics HART Ex, ext. p. b., v2.0

      4-20mA, version 2.0. Push button on housing. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Bestellnummer 52024400

      Electronics HART Ex, v2.0

      4-20mA, version 2.0. Push button on electronics. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Bestellnummer 71026358

      Electronics HART Ex, v2.10

      4-20mA, version 02.10.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Bestellnummer 71026359

      Electronics HART Ex, ext. p. b., v2.10

      4-20mA, version 02.10.zz. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Bestellnummer 71196092

      Electronic HART Ex, v2.11

      4-20mA, version 02.11.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Bestellnummer 71196093

      Electronics HART Ex, ext. p. b., v2.11

      4-20mA, version 2.11.zz. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Bestellnummer 71263933

      Electronics HART Ex, v2.20

      4-20mA. Software version 02.20.zz, HART 7, DevRev22. Push button on electronics. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Bestellnummer 71263934

      Electronics HART Ex, ext. p. b., v2.20

      4-20mA. Software version 02.20.zz, HART 7, DevRev22. Push button on housing. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Bestellnummer 71386147

      Elektronics HART Ex, v2.30

      4-20mA. Software version 02.30.zz, HART 7, DevRev23. Push button on electronics. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Bestellnummer 71386153

      Electronics HART Ex, ext. p. b., v2.30

      4-20mA. Software version 02.30.zz, HART 7, DevRev23. Push button on housing. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Bestellnummer 52026762

      Upgrade electronics HART Ex, v2.1

      Consists of: electronics HART Ex, version 2.1. Push button on electronics. Display housing. Usage: conversion electronics 1.0 > 2.1, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Bestellnummer 52026763

      Upgrade electr. HART Ex,ext.push b.,v2.1

      Consists of: electronics HART Ex, version 2.1. Push button external. Push button, housing HART version 2. Display housing. Usage: conversion electronics 1.0 > 2.1, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 30
    • Nr 30 Bestellnummer 71071824

      Electronics PA, HW02.00, SW4.0

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Bestellnummer 71071825

      Electronics PA, ext. p.b., HW02.00,SW4.0

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Bestellnummer 71071826

      Electronics FF, HW2.00, SW3.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on electronics. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Bestellnummer 71071827

      Electronics FF, ext. p.b., HW2.00,SW3.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on housing. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Bestellnummer 71214057

      Electronics PA, Ex, HW2.00, SW3.00

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Bestellnummer 71214064

      Electronics PA, ext. p.b.,HW2.00, SW3.00

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Bestellnummer 71214066

      Electronics FF, ext. p.b.,HW2.00, SW2.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 02.00.zz. Current consumption 15mA +/-1mA. Push button on housing. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Bestellnummer 71214069

      Electronics FF, HW2.00, SW2.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 02.00.zz. Current consumption 15mA +/-1mA. Push button on electronics. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Bestellnummer 71214890

      Electronics FF, ext. p.b.,HW2.00, SW4.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 04.00.zz, FF, DevRev07. Current consumption 15mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for SIL.

    • Nr 30 Bestellnummer 71214892

      Electronics FF, HW2.00, SW4.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 04.00.zz, FF, DevRev07. Current consumption 15mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for SIL.

    • Nr 30 Bestellnummer 71224775

      Electronics PA, HW02.00, SW4.01

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.01.zz, PROFIBUS PA, Profile 3.02, DevRev03. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Bestellnummer 71224776

      Electronics PA, ext.p. b.,HW02.00,SW4.01

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.01.zz, PROFIBUS PA, Profile 3.02, DevRev03. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 31
    • Nr 31 Bestellnummer 52027785

      HistoROM / M-DAT, 16K

      Setup-/diagnostic software included. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 35
    • Nr 35 Bestellnummer 52020434

      Terminal 3-pole, RFI, HART, TIIS

      RFI-filter. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75, TIIS Ex ia.

    • Nr 35 Bestellnummer 52026605

      Terminal 2-pole, RFI, PA, TIIS

      RFI filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMD70/PMD75, PMP71/PMP75. TIIS Ex ia, TIIS Ex d. PMC71, TIIS Ex ia.

    • Nr 35 Bestellnummer 52027691

      Terminal 2-pole, RFI, FF, Ex

      RFI-filter. FOUNDATION Fieldbus. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 35 Bestellnummer 71028473

      Terminal 3p., RFI, HART, OVP, TIIS

      Overvoltage protection, RFI-filter. Usage: FMB70, FMD76/FMD77/FMD78, PMD70/PMD75, PMP71/PMP75.

    • Nr 35 Bestellnummer 71028475

      Terminal 2-pole, RFI, PA, OVP, Ex

      Overvoltage protection, RFI-filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 35 Bestellnummer 71028476

      Terminal 2-pole, RFI, FF, OVP, Ex

      Overvoltage protection, RFI-filter. FOUNDATION Fieldbus. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 35 Bestellnummer 71121574

      Terminal 2-pole, RFI, PA, Ex

      RFI filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for TIIS.

    • Nr 35 Bestellnummer 71191892

      Terminal 3-pole,Li=0, RFI,HART,Ex ia/Exd

      RFI-filter. Not for TIIS Ex ia, TIIS Ex d. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 35 Bestellnummer 71191894

      Termin.3-p.,Li=0,RFI,HART,OVP,Ex ia/Exd

      Overvoltage protection, RFI-filter. Not for TIIS Ex ia, TIIS Ex d. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 40
    • Nr 40 Bestellnummer 71002865

      Display module VU340, Cbar/Dbar/Dpilot S

      Digital display, 3 push buttons, snapped bracket. Languages DE/EN/FR/ES/IT/NL, from software version 02.00.zz; Usage: electronics HART. Languages DE/EN/FR/ES/IT/NL/JA/ZH. From software version 02.01.zz; Electronics HART. Languages DE/EN/FR/ES/IT/JA/ZH/RU, from software version 02.11.zz; Electronics HART. From software version 04.00.zz; Electronics PROFIBUS PA. From software version 03.00.zz; Electronics FOUNDATION Fieldbus, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75. From software version 01.00.zz; Electronics HART, FMD71/FMD72.

    • Bestellnummer 71102216

      Mountingset Cerabar,Deltapilot,Levelflex

      Material: 316L. Usage: wall/pipe mounting (2"), FMB50/FMB51/FMB52/FMB53, FMB70, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, PMC51, PMC71, PMP51/PMP55, PMP71/PMP75.

    • Bestellnummer 71304770

      Mountingset, housing T14, special

      Material: 316L. Usage: mounting kit to attach the own mounting bracket / weather protection cover, FMB70, PMC71, PMP71/PMP75.

    • Bestellnummer 71043886

      Cable PE, L=2m/80inch, separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Bestellnummer 71043888

      Cable PE, L=5m/200inch, separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Bestellnummer 71043889

      Cable PE, L=10m/400inch,separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Bestellnummer 71070738

      Cable FEP, L=5m/200inch,separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Bestellnummer 52023572

      Profile gasket silicone, 5 pieces

      Process gasket universal process adapt. FDA listed. Usage: FMB50, FMB70, FMI51/FMI52, FTI51/FTI52/FTI55, PMC51.

    • Bestellnummer 52002041

      Weld-in adapter DRD DN50, 316L

      Front-flush mounting of devices with DRD flange. Material: 316L. Seal: PTFE flat. FDA compliant. Usage: FMB50, FMB70, FMD78, FTL50/FTL50H/FTL51/FTL51C/FTL51H, PMC51, PMC71, PMP51/PMP55, PMP75.

    • Bestellnummer 71377369

      Flushing ring NPS 1" Cl. 150-2500, 316L

      Consists of: 2x flushing ring connection. Thread ASME FNPT 1/2. Usage: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.

    • Bestellnummer 71377370

      Flushing ring NPS 2" Cl. 150-2500, 316L

      Consists of: 2x flushing ring connection. Thread ASME FNPT 1/2. Usage: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.

    • Bestellnummer 71377371

      Flushing ring NPS 3" Cl. 150-2500, 316L

      Consists of: 2x flushing ring connection. Thread ASME FNPT 1/2. Usage: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.

    • Bestellnummer 71377379

      Flushing ring DN25, PN16-400, 316L

      Consists of: 2x flushing ring connection. Thread ASME FNPT 1/2. Usage: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.

    • Bestellnummer 71377380

      Flushing ring DN50, PN16-400, 316L

      Consists of: 2x flushing ring connection. Thread ASME FNPT 1/2. Usage: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.

    • Bestellnummer 71377383

      Flushing ring DN80, PN16-400, 316L

      Consists of: 2x flushing ring connection. Thread ASME FNPT 1/2. Usage: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.

    • Bestellnummer 71007843

      ToF Adapter FXA291

      Usage: connection Micropilot M, Micropilot S, Levelflex M, Prosonic M, Tank Side Monitor, Deltabar S, Cerabar S, Gammapilot M, Micropilot I, to Commubox FXA291.

    • Bestellnummer 71000221

      Adapterk. FMR2xx,FMx4x,PMx7x,FMD7x,FMG60

      Connection service tool RS232(52013675)/ ToF adapter FXA291 (71007843). Usage: FMG60, FMD77/FMD78, FMR230/ FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44, NRF590, PMC71, PMD75, PMP71/PMP75.

    • Bestellnummer XPRFID-

      Spare RFID TAG

      Consists of: RFID TAG, fixing wire, crimp sleeve.

  • Predhodnik