Single-use media preparation

Explore measurement points and instrument selection across the single-use media preparation process

M F D T F D T F T A Cond AX A pH Komponente A WFI Komponente B J - Medienherstellung (Single-use) Component A WFI Component B J - Single-use media preparation
Component A Feed
Flow Component B Feed
WFI Feed
Media Temperature Measurement
Media Conductivite Measurement
Raman Analyzer
Media pH Measurement
Pretok merjenje v: Component A Feed

Endress+Hauser ponuja nabor analitskih instrumentov, ki so idealni za to fazo.

warning sign Ni na voljo

Splošne zahteve:

  • High reproducibility over a large flow range
  • Suitable for measuring WFI (water for injection)
  • Measure changing fluids w/o readjustment
  • Real time density measurement with high accuracy

Tehnične zahteve:

  • Measuring task: Liquids
  • Process temperature: max 40°C (104°F)
  • Density: 0.9 to 1.5 g/cm³
Pretok merjenje v: Flow Component B Feed

Endress+Hauser ponuja nabor analitskih instrumentov, ki so idealni za to fazo.

warning sign Ni na voljo

Splošne zahteve:

  • High reproducibility over a large flow range
  • Suitable for measuring WFI (water for injection)
  • Measure changing fluids w/o readjustment
  • Real time density measurement with high accuracy

Tehnične zahteve:

  • Measuring task: Liquids
  • Process temperature: max 40°C (104°F)
  • Density: 0.9 to 1.5 g/cm³
merjenje v: WFI Feed

Endress+Hauser ponuja nabor analitskih instrumentov, ki so idealni za to fazo.

warning sign Ni na voljo

Splošne zahteve:

  • High reproducibility over a large flow range
  • Suitable for measuring WFI (water for injection)

Tehnične zahteve:

  • Measuring task: Liquids
  • Process temperature: max 40°C (104°F)
  • Density: 0.9 to 1.5 g/cm³
Temperatura merjenje v: Media Temperature Measurement

Endress+Hauser ponuja nabor analitskih instrumentov, ki so idealni za to fazo.

Alternative:

Splošne zahteve:

  • High accuracy
  • Wide measurement range
  • Fast response time

Tehnične zahteve:

  • Measuring task: Thermometer
  • Process temperature: max 40°C (104°F)
  • Density: 0.9 to 1.5 g/cm³
Analiza merjenje v: Media Conductivite Measurement

Endress+Hauser ponuja nabor analitskih instrumentov, ki so idealni za to fazo.

Splošne zahteve:

  • High accuracy
  • Wide measurement range
  • Fast response time

Tehnične zahteve:

  • Measuring task: Conductivity
  • Process temperature: max 40°C (104°F)
  • Density: 0.9 to 1.5 g/cm³
Analiza merjenje v: Raman Analyzer

Endress+Hauser ponuja nabor analitskih instrumentov, ki so idealni za to fazo.

Splošne zahteve:

  • Multiparameter measurement
  • Non-destructive
  • Rapid quality evaluation
  • Suitable for analysis of solids and liquids

Tehnične zahteve:

Analiza merjenje v: Media pH Measurement

Endress+Hauser ponuja nabor analitskih instrumentov, ki so idealni za to fazo.

Alternative:

Splošne zahteve:

  • High accuracy
  • Easy and accurate calibration

Tehnične zahteve:

  • Measuring task: pH
  • Process temperature: max 40°C (104°F)
  • Density: 0.9 to 1.5 g/cm³
lorem ipsum ©Endress+Hauser

Key instrumentation challenges in single-use media preparation

In single-use media preparation the biggest challenges are usually no the mixing bag itself, but the quality and reliability of the measurements use to verify media preparation. Media preparation remains one of the least-measured unit operations in single-use bioprocessing.

  • Obtaining reliable pH measurements in disposable systems: Disposable pH sensors can exhibit drift, limited calibration capability and lower reliability compared with conventional reusable probes.
  • Verifying complete powder dissolution and mixing homogeneity: Instrumentation often cannot directly confirm that all powder is dissolved and uniformly distributed.
  • Accurate bag volume/level measurement: Flexible bags change shape during filling and emptying, making precise level measurement difficult.
  • Maintaining data integrity with single-use sensors: Disposable instrumentation must still meet GMP data requirements while integrating into plant automation systems.
Media preparation portfolio highlights

Explore our innovations for your single-use media preparation process