Za začetek iskanja vnesite vsaj dva znaka.
  • Zgodovina

TH51
Modular TC thermometer, US style

TH51
Modular TC thermometer, US style ©Endress+Hauser

Best in class temperature measurement technology for general applications

The high modular thermometer is used for several applications in almost all industries. Examples are heat exchangers, furnaces, dryers, process reactors, etc. With different head transmitter it's a complete unit ready for use with enhanced measurement accuracy and reliability. It also enables very fast response times, due to direct contact measurement without thermowell. A variety of process connections and dimensions offer flexible application possibilities.

  • Enostavni produkti

  • Lahka izbira, vgradnja in uporaba

Tehnična odličnost

Preprostost

  • Standardni produkti

  • Zanesljivi, robustni, nezahtevni za vzdrževanje

Tehnična odličnost

Preprostost

  • Vrhunski produkti

  • Visoko funkcionalni in praktični

Tehnična odličnost

Preprostost

  • Specialni produkti

  • Zasnovani za posebej zahtevne aplikacije

Tehnična odličnost

Preprostost

Spremenljivo

FLEX izbira Tehnična odličnost Preprostost
  • F
  • L
  • E
  • X

Segment Fundamental

Zadostite svojim osnovnim merilnim potrebam

Tehnična odličnost
Preprostost
  • F
  • L
  • E
  • X

Segment Lean

Obvladajte ključne procese na preprost način

Tehnična odličnost
Preprostost
  • F
  • L
  • E
  • X

Segment Extended

Optimirajte procese z inovativnimi tehnologijami

Tehnična odličnost
Preprostost
  • F
  • L
  • E
  • X

Segment Xpert

Imejte pod nadzorom najzahtevnejše aplikacije

Tehnična odličnost
Preprostost

Spremenljivo

  • Lastnosti na dlani

    • Accuracy

      Standard acc. to ASTM E-230
      Special acc. to ASTM E-230

    • Response time

      63% rt = 0.3 s

    • Max. process pressure (static)

      at 20°C: 250 bar (3.626 psi)
      depends on configuration

    • Operating temperature range

      Type T:
      -270 °C ...370 °C
      (-454 °F ...698 °F)
      Type J:
      -210 °C ...720 °C
      (-346 °F ...1.328 °F)
      Type E:
      -270 °C ...820 °C
      (-454 °F ...1.508 °F)
      Type K:
      -270 °C ...1.150 °C
      (-454 °F ...2.102 °F)
      Type N:
      -270 °C ... 1.150 °C
      (-454 °F ...2.102 °F)

    • Max. immersion length on request

      up to 96" (2.438 mm)
      others on request

Hitra izbira

Izberite med predlaganimi možnostmi
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

ali

Individualna konfiguracija

Nadaljujte z izbiranjem med vsemi možnostmi
  • Prednosti

    • One source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering. Remove and install straight out of the box!

    • Improved galvanic isolation on most devices (2 kV)

    • Simplified model structure: Competitively...

  • Področje uporabe

    Magnesium oxide insulated thermocouples, commonly referred to as MgO thermocouples, are used in many process and laboratory applications. They have many desirable characteristics making thermocouples a good choice for general and special purpose...

Lastnosti in specifikacije

Nazaj

Podrobnosti

  • Merilni princip

    Thermocouple

  • Characteristic / Application

    US style

    modular temperature assembly

    threaded process connection

  • Thermowell / protection tube

    without (not intended to use with thermowell)

  • Insert / probe

    mineral insulated (MI), flexible

  • Outer diameter protection tube / Insert

    1/8'' (3,18 mm)

    3/16''(4,76 mm)

    1/4'' (6,35 mm)

    3/8'' (9,53 mm)

  • Max. immersion length on request

    up to 96" (2.438 mm)

    others on request

  • Material protection tube/ thermowell

    316

    Alloy 600

  • Optional coating

    Not applicable

  • Process connection

    male thread:

    G1/2"

    NPT1/2"

    compression fitting:

    NPT1/8"

    NPT1/4"

  • Tip shape

    straight

  • Surface roughness Ra

    Not defined

  • Operating temperature range

    Type T:

    -270 °C ...370 °C

    (-454 °F ...698 °F)

    Type J:

    -210 °C ...720 °C

    (-346 °F ...1.328 °F)

    Type E:

    -270 °C ...820 °C

    (-454 °F ...1.508 °F)

    Type K:

    -270 °C ...1.150 °C

    (-454 °F ...2.102 °F)

    Type N:

    -270 °C ... 1.150 °C

    (-454 °F ...2.102 °F)

  • Max. process pressure (static)

    at 20°C: 250 bar (3.626 psi)

    depends on configuration

  • Accuracy

    Standard acc. to ASTM E-230

    Special acc. to ASTM E-230

  • Response time

    63% rt = 0.3 s

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    transmitter only

    FM IS

    CSA IS

    FM/CSA IS

  • Certification

    SIL (transmitter only)

Dokumenti / Priročniki / Softver

Pribor / Nadomestni deli

Št.
Kataloška koda
Specifikacija
  • A
  • A
    • Kataloška koda TU301-

      Compression Fitting, threaded TU301

    • Kataloška koda TXU10-

      Configuration Kit TXU10

      for PC-programmable devices. set-up programme+interface cable for PC with USB-Port.

    • Kataloška koda FXA195-

      Commubox FXA195

      Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.

    • Kataloška koda READWIN-

      Readwin 2000 Operation + Read. software

    • Kataloška koda TMT181-

      iTEMP TMT181, Head Transmitter PCP

      Product being phased out, limited availability. Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Kataloška koda TMT182-

      iTEMP TMT182, Head Transmitter HART

      Product being phased out, limited availability. Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanicisolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Kataloška koda TMT85-

      iTEMP TMT85, Transmitter FF

      Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Kataloška koda XPT0004-

      Spare Parts Kit Cover TA30R

      cover of connecting head

  • A
    • Št. A Kataloška koda TA30H-

      Terminal Head TA30H

      Retainer for terminal block or head transmitter + optional display. Design: explosion proof. Cover: screwed, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50 150 oC (housing). Protection: IP66/68, NEMA 4X (housing). Protection Ex d/XP: IP66/67 (housing).

    • Št. A Kataloška koda TA30R-

      Terminal Head TA30R

      Retainer for terminal block or head transmitter + optional display. Cover: screwed, optional window. Material: Stainless Steel 316L. Colour: Steel (no coating). Ambient Temp.: -50...85/130 oC (display/standard). Protection: IP66/68, NEMA4X; IP69K (housing). :: easy wiring through best accessibility. :: compact desing and low weight.

  • A
    • Kataloška koda TMT71-

      iTEMP TMT71, Transmitter 4-20mA

      2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.

    • Kataloška koda TMT72-

      iTEMP TMT72, Transmitter HART

      2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.

    • Kataloška koda TMT82-

      iTEMP TMT82, Transmitter HART

      2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.

    • Kataloška koda TMT84-

      iTEMP TMT84, Transmitter PA

      Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Kataloška koda TID10-

      Display Unit Head Transmitter

      to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84, TMT82.