Za začetek iskanja vnesite vsaj dva znaka.
  • Zgodovina

Digital conductivity sensor
Indumax CLS54D

Digital conductivity sensor
Indumax CLS54D ©Endress+Hauser
Digital conductivity sensor
Indumax CLS54D Side View ©Endress+Hauser
Digital conductivity sensor
Indumax CLS54D Close-Up ©Endress+Hauser

The conductivity of a liquid can be measured using the conductive or toroidal measuring principles. This video shows what it is about and how these measuring principles work.

Memosens toroidal conductivity sensor for hygienic and sterile applications

The Indumax CLS54D inductive conductivity sensor protects all of your products and processes that must meet the strictest hygienic and sterile demands. Its outstanding performance combined with a unique hygienic design ensures highest safety and quality of your products. Thanks to Memosens digital technology, Indumax CLS54D combines maximum process and data integrity with simple operation. It resists corrosion and moisture, enables lab calibration, and facilitates predictive maintenance.

  • Enostavni produkti

  • Lahka izbira, vgradnja in uporaba

Tehnična odličnost

Preprostost

  • Standardni produkti

  • Zanesljivi, robustni, nezahtevni za vzdrževanje

Tehnična odličnost

Preprostost

  • Vrhunski produkti

  • Visoko funkcionalni in praktični

Tehnična odličnost

Preprostost

  • Specialni produkti

  • Zasnovani za posebej zahtevne aplikacije

Tehnična odličnost

Preprostost

Spremenljivo

FLEX izbira Tehnična odličnost Preprostost
  • F
  • L
  • E
  • X

Segment Fundamental

Zadostite svojim osnovnim merilnim potrebam

Tehnična odličnost
Preprostost
  • F
  • L
  • E
  • X

Segment Lean

Obvladajte ključne procese na preprost način

Tehnična odličnost
Preprostost
  • F
  • L
  • E
  • X

Segment Extended

Optimirajte procese z inovativnimi tehnologijami

Tehnična odličnost
Preprostost
  • F
  • L
  • E
  • X

Segment Xpert

Imejte pod nadzorom najzahtevnejše aplikacije

Tehnična odličnost
Preprostost

Spremenljivo

  • Lastnosti na dlani

    • Measurement range

      100 µS/cm to 2000 mS/cm
      Cell constant k: 6.3 1/cm

    • Process temperature

      -10 °C to 125 °C (14 °F to 257 °F)
      Sterilization: 150 °C at 6 bar abs for max. 60 min
      (302 °F at 87 psi abs for max. 60 min)

    • Process pressure

      13 bar abs up to 90 °C (188.5 psi abs up to 194 °F)
      9 bar at 125 °C (130.5 psi abs at 257 °F)

please wait Loading alternative products

Hitra izbira

Izberite med predlaganimi možnostmi
Prodajna cena
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

ali

Individualna konfiguracija

Nadaljujte z izbiranjem med vsemi možnostmi
  • Prednosti

    • Unique hygienic design avoids contamination

    • With all hygienic certificates required in hygienic and sterile applications, compliant with EG 2023/2006 and 1935/2004

    • Food grade virgin PEEK body without joints nor crevices

    • Certified biocompatibility according...

  • Področje uporabe

    Indumax CLS54D measures toroidal conductivity in hygienic food & beverage and life science applications, such as:

    • Phase separation of product/water and product/product mixtures in pipe systems

    • Control of CIP (cleaning in place) processes in the return...

Lastnosti in specifikacije

Nazaj

Podrobnosti

  • Merilni princip

    Inductive

  • Application

    Food, beverage and pharmaceutical industries, biotechnology, dairies, breweries

  • Characteristic

    Specifically intended for use in hygienic applications and especially suitable for following applications:
    Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring

  • Measurement range

    100 µS/cm to 2000 mS/cm
    Cell constant k: 6.3 1/cm

  • Measuring principle

    Inductive conductivity measurement

  • Design

    Hygienic design with food-grade virgin PEEK body in jointless and creviceless design including all hygienic certifications

  • Material

    In contact with medium: virgin PEEK

  • Process temperature

    -10 °C to 125 °C (14 °F to 257 °F)
    Sterilization: 150 °C at 6 bar abs for max. 60 min

    (302 °F at 87 psi abs for max. 60 min)

  • Process pressure

    13 bar abs up to 90 °C (188.5 psi abs up to 194 °F)

    9 bar at 125 °C (130.5 psi abs at 257 °F)

  • Temperature sensor

    Pt1000 (Class A according to IEC 60751)

  • Connection

    Dairy pipe, Aseptic-fitting, Clamp ISO 2852, SMS-2", Varivent N DN 40-125, Neumo Biocontrol D50

  • Ingres protection

    IP68 / NEMA type 6P

  • Additional certifications

    FDA, EHEDG, 3-A
    Biological reactivity USP class VI part <87> and <88>

Dokumenti / Priročniki / Softver

Pribor / Nadomestni deli

Št.
Kataloška koda
Specifikacija
    • Kataloška koda 50081902

      Calibration solution CLY11-A, 74,0 uS/cm

      500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO

    • Kataloška koda 50081903

      Calibration solution CLY11-B,149,6 uS/cm

      500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO.

    • Kataloška koda 50081904

      Calibration solution CLY11-C,1,406mS/cm

      500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO

    • Kataloška koda 50081905

      Calibration solution CLY11-D,12,64 mS/cm

      500 ml, reference temperature 25oC. Precision solution referred to SRM to NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO

    • Kataloška koda 50081906

      Calibration solution CLY11-E,107,00mS/cm

      500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO