Field of application
FlexView FMA90 is a control unit for radar, ultrasonic and hydrostatic or universal 4-20 mA level sensors. It connects up to two sensors simultaneously and provides 8 digital switching outputs. Available in field, DIN rail and panel housing variants, it ensures seamless installation in field and control cabinet environments. Its robust design and intuitive touch control make it ideal for versatile applications in the Water, Wastewater & Waste sector and utility operations across all industries.
FlexView FMA90 is suitable for a wide range of applications:
Open channel flow under changing weather conditions
Rake control with occurring suspended solids or sediments
Pump control in narrow installation conditions
Storm water basin in remote measuring locations
Benefits
Flexible use with up to two level sensors across multiple technologies
High cybersecurity due to integrated software features
Remote access to hard-to-reach measurement points thanks to Wi-Fi connectivity
Ease of use thanks to intuitive 3.5" color display with touch control operable with gloves
Fast commissioning with guided setup sequences, tutorials and automatic sensor detection
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity |
|---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
Measuring principle
Hydrostatic pressure
-
Characteristic
Level, pump control, open channel flow measurement, data logging, rake control, storm overflow basin
-
Supply voltage
100 … 230 VAC;
10.5 … 32 VDC -
Ambient temperature
-40 to +60 °C (-40 to +140 °F) (Type tested);
-35 to +60 °C (-31 to +140 °F) (approved by CSA) -
Communication
Input:
1x or 2 x 4-20mA/HART
Output:
2 x Analog,
1 relay or 5 relays (2 x SPDT, 3 x SPST),
1 or 3 open collector (NPN) -
Certificates / Approvals
ATEX, CSA, EAC, JPN Ex, NEPSI, INMETRO
-
Specialities
Degree of protection of polycarbonate field housing;
and aluminum field housing: IP65/NEMA Type 4x;
Degree of protection of DIN rail housing: IP20;
Degree of protection of panel housing: IP65/NEMA Type 4 (at front,;
if mounted in cabinet door), IP20 (at rear, if mounted in cabinet door);
sensor recognition and parameter mapping;
of FMR20B/FMR30B/FMX21 sensors
-
Measuring principle
Level radar
-
Characteristic / Application
Level, pump control, open channel flow measurement, data logging, rake control, storm overflow basin
-
Specialities
Degree of protection of polycarbonate field housing;
and aluminum field housing: IP65/NEMA Type 4x;
Degree of protection of DIN rail housing: IP20;
Degree of protection of panel housing: IP65/NEMA Type 4 (at front,;
if mounted in cabinet door), IP20 (at rear, if mounted in cabinet door);
sensor recognition and parameter mapping;
of FMR20B/FMR30B/FMX21 sensors -
Supply / Communication
100 … 230 VAC;
10.5 … 32 VDC -
Ambient temperature
-40 to +60 °C (-40 to +140 °F) (Type tested);
-35 to +60 °C (-31 to +140 °F) (approved by CSA) -
Communication
Input:
1x or 2 x 4-20mA/HART
Output:
2 x Analog,
1 relay or 5 relays (2 x SPDT, 3 x SPST),
1 or 3 open collector (NPN) -
Certificates / Approvals
ATEX, CSA, EAC, JPN Ex, NEPSI, INMETRO
-
Options
3.5" TFT touch color display for onsite operation with backlight, WLAN connectivity or communication via Ethernet, guided wizzards vor commissioning, up to two level sensors
Housing:
Panel-mounted / DIN rail / Field -
Components
Sensors: FMR10B, FMR20B, FMR30B, FMX21, FMU30
-
Measuring principle
Level radar solid
-
Characteristic / Application
Level, pump control,open channel flow measurement, data logging, rake control, storm overflow basin
-
Specialities
Degree of protection of polycarbonate field housing;
and aluminum field housing: IP65/NEMA Type 4x;
Degree of protection of DIN rail housing: IP20;
Degree of protection of panel housing: IP65/NEMA Type 4 (at front,;
if mounted in cabinet door), IP20 (at rear, if mounted in cabinet door);
sensor recognition and parameter mapping;
of FMR20B/FMR30B/FMX21 sensors -
Supply / Communication
100 … 230 VAC;
10.5 … 32 VDC -
Ambient temperature
–40 to +60 °C (–40 to +140 °F) (Type tested);
–35 to +60 °C (–31 to +140 °F) (approved by CSA) -
Communication
Input:
1x or 2 x 4-20mA/HART
Output:
2 x Analog,
1 relay or 5 relays (2 x SPDT, 3 x SPST),
1 or 3 open collector (NPN) -
Certificates / Approvals
ATEX, CSA, EAC, JPN Ex, NEPSI, INMETRO
-
Options
3.5" TFT touch color display for onsite operation with backlight, WLAN connectivity or communication via Ethernet, guided wizzards vor commissioning, up to two level sensors
Housing:
Panel-mounted / DIN rail / Field -
Components
Sensors: FMR10B, FMR20B, FMR30B, FMX21, FMU30
-
-
Technical Information (TI)
TI FlexView FMA90
-
Technical Information (TI)
English version - 05/2025New version available in EnglishControl unit
EN 31/05/202524/12/2022Language:
English
Version:
31/05/2025
File size:
4.2 MB
File name:
TI01689FEN_0225-00.pdf
-
-
-
Operating Instruction (BA)
BA FlexView FMA90
-
Operating Instruction (BA)
English version - 12/2022New version available in EnglishControl unit with color display and touch control for up to two ultrasonic, radar, hydrostatic or universal 4-20 mA/HART level senso
rsEN 29/12/2022Language:
English
Version:
29/12/2022
File size:
10.8 MB
File name:
BA02254FEN_0122-00.pdf
-
-
-
Device Parameter (GP)
GP FlexView FMA90
-
Device Parameter (GP)
English version - 12/2024New version available in EnglishControl unit with color display and touch control for up to two ultrasonic, radar, hydrostatic or universal 4-20 mA/HART® level sens
orsEN 01/12/2024Language:
English
Version:
01/12/2024
File size:
1.9 MB
File name:
GP01189FEN_0122-00.pdf
-
-
-
Short Instruction (KA)
KA FlexView FMA90 control unit, HART®
-
Short Instruction (KA)
English version - 05/2025New version available in EnglishControl unit for field mounting, DIN rail mounting or panel mounting with graphic display and touch operation for up to two ultrason
ic, radar, hydrostatic or universal 4 to 20 mA/HART level sensorsEN 31/05/202530/05/2025Language:
English
Version:
31/05/2025
File size:
4.6 MB
File name:
KA01584FEN_0325-00.pdf
-
-
-
Installation Instructions (EA)
EA CPU-Board FMA90 Panel
-
Installation Instructions (EA)
English version - 11/2025New version available in EnglishEA CPU-Board FMA90 Panel
Language:
English
Version:
19/11/2025
File size:
4 MB
File name:
EA_CPU_FMA90_Panel_XPF0053_en_we.pdf
-
-
-
Installation Instructions (EA)
EA Front+Display FMA90 DIN Rail
-
Installation Instructions (EA)
English version - 11/2025New version available in EnglishEinbauanleitung für Front+Display FMA90 DIN Rail
EN 20/11/202519/11/2025Language:
English
Version:
20/11/2025
File size:
4 MB
File name:
EA_Front_Display_71706829_71706830_DIN Rail_en_we.pdf
-
-
-
Installation Instructions (EA)
EA Battery
-
Installation Instructions (EA)
English version - 08/2025New version available in EnglishEA Battery
Language:
English
Version:
05/08/2025
File size:
188.8 KB
File name:
EA_FMA90_Battery_en.pdf
-
-
-
Installation Instructions (EA)
EA Release Code XPF0054
-
Installation Instructions (EA)
English version - 10/2025New version available in EnglishEA Release Code XPF0054
Language:
English
Version:
10/10/2025
File size:
119.7 KB
File name:
Release code FMA90.pdf
-
-
-
Installation Instructions (EA)
EA Front + Display FMA90 DIN Rail
-
Installation Instructions (EA)
English version - 01/2026New version available in EnglishEinbauanleitung Front + Display FMA90 DIN Rail
Language:
English
Version:
08/01/2026
File size:
4 MB
File name:
EA_Front_Display_71706829_71706830_DIN Rail_en_we.pdf
-
-
-
Installation Instructions (EA)
EA Bus Board FMA90 Panel
-
Installation Instructions (EA)
English version - 01/2026New version available in EnglishEinbauanleitung Bus Board FMA90 Panel
Language:
English
Version:
08/01/2026
File size:
4 MB
File name:
EA_Bus Board _FMA90_Panel_71706838_en_we.pdf
-
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together