This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
-
Successor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
US style
modular temperature assembly
hygienic design
hygienic process connection
incl. thermowell / protection tube (metal) -
Thermowell / protection tube
bar stock (drilled)
-
Insert / probe
mineral insulated (MI), flexible
-
Outer diameter protection tube / Insert
1/2'' (12,70 mm)
3/4'' (19,05 mm) -
Max. immersion length on request
up to 2.743 mm (108,00'')
-
Material protection tube/ thermowell
1.4404 (316L)
-
Process connection
hygienic:
clamp connections TRI-Clamp / Micro-Clamp -
Tip shape
straight
reduced -
Surface roughness Ra
0,8 μm (32 μin.)
-
Operating temperature range
PT 100:
-50 °C ...200 °C
(-58 °F ... 392 °F) -
Max. process pressure (static)
at 20 °C: 100 bar (1.450 psi)
-
Accuracy
class A acc. to IEC 60751
class B acc. to IEC 60751 -
Response time
depending on configuration
-
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex - approvals
CSA
FM/CSA IS
FM IS -
Certification
3A
FDA
ASME BPE 2002
SIL (transmitter only)